Single frame suspended - T-45 + PL profiles

Suspended ceiling made up of a frame of galvanised sheet steel profiles over a base of Pladur® T-45 profiles or mullions hung from the framing by means of Pladur® standard reach brackets + Ø 6 mm threaded rod, and supported by Pladur® profiles attached mechanically along the whole perimeter. One or two Pladur® plasterboards are screwed to this frame. Commensurate amounts of Pladur® materials: screws, compounds, joint tape, resilient joints, etc. Completely finished with Quality Level 2 (Q2), Level 3 (Q3), Level 4 (Q4), according to the surface finish (to be determined by the design). Installed according to Pladur® recommendations, UNE 102043 Standard and CTE requirements.

Single frame suspended - T-45 + PL profiles
8 items found

Filters

Categories
Single frame suspended - T-45 + PL profiles
Plasterboard
Board thickness (mm)
Maximum hanger span

Suspended single frame ceiling Pladur® T-45+PL-75 1x15 N MW

System weigh: 14 kg/m²

Maximum distance between hangers: 1100 mm

Airborne noise insulation - RA: 65 dBA

Impact noise insulation - Ln,w: 71 dB

Suspended single frame ceiling Pladur® T-45+PL-75 1x15 H1 MW

System weigh: 14.9 kg/m²

Maximum distance between hangers: 1100 mm

Airborne noise insulation - RA: 65 dBA

Impact noise insulation - Ln,w: 71 dB

Suspended single frame ceiling Pladur® T-45+PL-75 1x12,5 ULTRA L-TEC MW

System weigh: 9.8 kg/m²

Maximum distance between hangers: 1100 mm

Suspended single frame ceiling Pladur® T-45+PL-75 2x12,5 N MW

System weigh: 22 kg/m²

Maximum distance between hangers: 900 mm

Airborne noise insulation - RA: 68 dBA

Impact noise insulation - Ln,w: 70 dB

Suspended single frame ceiling Pladur® T-45+PL-75 1x12,5 N MW

System weigh: 12 kg/m²

Maximum distance between hangers: 1100 mm

Airborne noise insulation - RA: 68 dBA

Impact noise insulation - Ln,w: 70 dB

Suspended single frame ceiling Pladur® T-45+PL-75 1x12,5 H1 MW

System weigh: 12 kg/m²

Maximum distance between hangers: 1100 mm

Airborne noise insulation - RA: 68 dBA

Impact noise insulation - Ln,w: 70 dB

Suspended single frame ceiling Pladur® T-45+PL-75 1x12,5 SYNIA STD 4BA MW

System weigh: 11.8 kg/m²

Maximum distance between hangers: 1100 mm

Airborne noise insulation - RA: 68 dBA

Impact noise insulation - Ln,w: 70 dB

Suspended single frame ceiling Pladur® T-45+PL-75 1x12,5 Air N MW

System weigh: 12 kg/m²

Maximum distance between hangers: 1100 mm

Airborne noise insulation - RA: 68 dBA

Impact noise insulation - Ln,w: 70 dB