Shaftwall partitions
Partition made up of a structure of galvanised sheet steel metal profiles 90 mm wide and 0.7 mm thick, with Pladur® CH-90 studs and Pladur® E-90 studs (vertical elements), spaced 600 mm on centre, and Pladur® J-92 channels (horizontal elements). Toward the inaccessible side (hollow area) a partition face is created enclosing a Pladur® CH plasterboard 25 mm thick with E-90 first and last studs with CH-90 studs in between, having, there being between both materials a continuous band of Pladur® intumescent acoustic sealant On the accessible side of this partition, one or more 15mm thick Pladur® F plasterboards are screwed on. Commensurate amounts of Pladur® materials: screws, compounds, joint tape, resilient/acoustic perimeter joints, etc., as well as anchors for channels on the floor and ceiling, etc. Completely finished with Quality Level 1 (Q1) for tile finishes, laminates, furring, etc. Also with Level 2 (Q2), Level 3 (Q3), Level 4 (Q4), according to the surface finish (to be determined by the design) except on the inaccessible side of the system. Core of each Pladur>® structure filled completely with mineral wool. Installed according to Pladur® recommendations, UNE 102043 Standard and CTE requirements.
Name
|
Maximum height
|
Fire resistance
|
Acoustic insulation - RA
|
System thickness
|
|
---|---|---|---|---|---|
|
|
Partition made up of a structure of galvanised sheet steel metal profiles 90 mm wide and 0.7 mm thick, with Pladur® CH-90 studs and Pladur® E-90 studs (vertical elements), spaced 600 mm on centre, and Pladur® J-92 channels (horizontal elements). Toward the inaccessible side (hollow area) a partition face is created enclosing a Pladur® CH plasterboard 25 mm thick with E-90 first and last studs with CH-90 studs in between, having, there being between both materials a continuous band of Pladur® intumescent acoustic sealant On the accessible side of this partition, one or more 15mm thick Pladur® F plasterboards are screwed on. Commensurate amounts of Pladur® materials: screws, compounds, joint tape, resilient/acoustic perimeter joints, etc., as well as anchors for channels on the floor and ceiling, etc. Completely finished with Quality Level 1 (Q1) for tile finishes, laminates, furring, etc. Also with Level 2 (Q2), Level 3 (Q3), Level 4 (Q4), according to the surface finish (to be determined by the design) except on the inaccessible side of the system. Core of each Pladur>® structure filled completely with mineral wool. Installed according to Pladur® recommendations, UNE 102043 Standard and CTE requirements.